Exhaust Fans
'Maxair' Exhaust Fans are perfect fans conditioning for any ventilation and pollution problem. 'Maxair' Exhaust fans are robust with low sound level and incorporate the best in fan engineering and design.The fan motor is totally enclosed with the rotor on ball bearing. 'Maxair' Exhaust fans conform to IS 2312 of 1967.Maxair' Fan offers widest ranges of Exhaust Fans in single & three phase with special treatment for corrosive, acidic or alkaline atmospheres.
| AIR DELIVERY | ||||||
Single Phase /Three Phase |
Speed |
Volts |
Power |
C.F.M. |
M3 per Hour |
|
9 |
(229) |
1350 |
220 |
40 |
440 |
750 |
Performance as per IS : 2312
Situation |
Recommended Air |
Size (mm) |
Air Charges |
Air Movement |
Maxair Exhaust |
|
Industrial |
mm-rpm |
|||||
| 1. Workshops 2. Laboratories |
12-20 8-12 |
15 x 20 x 8 10 x 8 x 4 |
20 12 |
20 x 2400 12 x 320 |
4 Nos. 2 Nos. |
450-900 300-1400 |
Commercial |
mm-rpm |
|||||
| 1. Assembly Halls 2. Banks 3.Canteens/Restaurants 4. Cinemas/Theaters 5. Hospitals (General Ward) 6. Offices 7. Photographic Dark Rooms 8. Kitchens & Toilets |
8-12 4-8 12-20 20-30 8-12 8-12 20-30 20-30 |
15x 20 x 4 20 x 10 x 8 20 x 10 x 8 30 x 20 x 10 20 x 15 x 8 10 x 10 x 4 4 x 3 x 4 3.5 x 4 x 4 |
12 8 15 20 10 10 25 30 |
12 x 1200 8 x 1600 15 x 1600 20 x 6000 10 x 2400 10 x 400 25 x 48 56 x 30 |
3 Nos. 3 Nos. 6 Nos. 27 Nos. 6 Nos. 2 Nos. 1 Nos. 1 Nos. |
450-900 450-900 380-1400 450-900 450-900 300-1400 300-1400 300-1400 |
Formula for fan Selection : No. of fans = Volume x No. of Air charges /hr. Air flow of fan